Click to select products by application
Pluton LW, manufactured in large quantities ( more than 25 000 units ), is reference for LWIR ( 8-12 µm ) scanning arrays and is battlefield-proven.
Sofradir is MCT technology allows operations in LWIR waveband, the preferred solution for ground-based applications.
This high-performance IDCA takes full advantage of Sofradir is state of the art technologies.
Standard configurations
- Integrated Detector Dewar Cooler Assemblies (IDDCA) with miniature Stirling-cycle rotary coolers, for compact, low power configuration.
- IDDCA with split Stirling-cycle linear cooler, for expanded lifetime & system integration facilitation.
Array Features
| Detector pitch | 28 µm x 43 µm | |
| Material spectral response | 0.8 µm - 10.3 µm | |
| Detector spectral response | 7.7 µm up to material cut-off (high pass cold filter) | |
| FPA Operating Temperature | 77K to 80K | |
ROIC Features
Selection:
parallel or serial electrical interface
Modes:
snap shot operation, direct injection input circuit, simultaneous mode (integrate while read), programmable integration time (> 4MC), bi-directional TDI scanning, random pixel deselection
Max charge handling capacity :
0.4 / 1.2 / 3.4 / 6.1 / 8.0 / 10.5 / 12.2 / 16.0 Million e- (for 100% well fill)
Number of output : 4
Pixel output rate : up to 6 MHz per output